Skip to content

Recognize trace endpoints connected to copper pours - #608

Open
ShiboSoftwareDev wants to merge 1 commit into
repro/net-trace-ends-in-pourfrom
fix/net-trace-ends-in-pour
Open

ShiboSoftwareDev wants to merge 1 commit into
repro/net-trace-ends-in-pourfrom
fix/net-trace-ends-in-pour

Conversation

@ShiboSoftwareDev

@ShiboSoftwareDev ShiboSoftwareDev commented Nov 27, 2026 •

Copy link
Copy Markdown
Contributor

Count a net trace as connected where its endpoint touches same-net copper fill on the same layer. This uses the pour contact test already used by the dangling-trace check.

On the routed iCE/Pi CM0 SBC, disconnected-endpoint reports drop from 149 to 6 when checking the same copper. The regression covers a different net, a different layer, a gap beyond the wire cap and a flat-ended trace. Full-board repro

Before After
Disconnected marker inside the ground pour Trace connected to the ground pour

Typecheck and all four focused tests pass. The full suite passed 818 of 819 tests. The DDR spacing snapshot expects 0.214 mm and reports 0.283 mm on both current main and this branch.